2010* Siemens Definition Flash STELLAR CT

QUICK LOOK:

◎  Tube A replaced in July 2023 and Tube B was replaced in January 2019 but is low-use.

          ◎  Current Tube Counts (1/22/24): Tube A: 110,804 scan seconds; Tube B: 226,335 scan seconds

◎  Loaded with software

          ◎  Entire gantry was replaced in 2015

2010 Siemens Definition Flash, STELLAR version CT Scanner

ID
77125
Type
CT Scanner
Manufacturer
Siemens
Model
Definition Flash, STELLAR version
Year of MFG
2010
Condition
Good

Details

Model Number
10430603
Condition Notes
This machine is in exceptional condition. The only noticeable blemish is a crack under the left gantry control panel.
Date of Availability
03/23/2024
Geographical Location
Boston
Are the software disk(s) present?
Yes
Is the equipment under service?
Yes
Software Revision Level
Syngo VA44A
Software Option Details
✩ ANY OPTIONS LISTED ARE 'PERMANENT.' ✩ GET WORKLIST CAP3D_FILTER_85D CAP3D_FILTER_MIP CAP3D _MAIN CAP3D_VOIMODE CARDIO_PRO CARDIO_RETRO BOLUS_TRACK CARE_DOSE SYNGO_GENERAL_LICENSE CAP3D_FILTER_VRT CAP3D_EDITOR MPPS SUPPORT VOLUME WORKFLOW EXTENDED_FOV CTAPP_MAIN UHR_03 UHR CAPSO BONEREMOVAL DICOM_SR_VIEWER CTAPP_FILTER_VRT CTAPP_FILTER_MIP CTAPP_FUSIONBASE CTAPP FUSIONCUIPVIEW CTAPP_FUSIONLAYOUT CARDIO_BESTPHASE_FINDING DUAL_ENERGY_SCAN_RECON CTAPP_FILTER_SSD CT_NEURO_DSA CTAPP_PCT_NEURO CTAPP_CVF _PHASEVIEWER VOL PERFUSION_SCAN MAX_POWER SCAN AUTOREGION CARE_DOSE_ADJUST CARE_DOSE_PROFILE CARE_DOSE_ DASHBOARD DEFINITION_ FLASH VOL PERFUSION CARDIOSEO CARDIO HALFBEAT SPIRAL HIGHPITCH CARE_DOSE_X_CARE CARE_DOSE AUTOKY SCAN GUIDE RECON SPINE REGION RECON_ITERATIVE_STEP1 DUAL ENERGY FAST MR_Support i
Current Tube Model
Straton
When was the tube last replaced?
09/16/2022
Is the Tube Arcing?
No
Tube Statistics or Information
Tube A: Installed: 07/11/23 Tube Serial Number 254172301 KWs Since Tube Install: 2.2276e + 006 Tube Scan Seconds: 110,804 System Scan Seconds: 1.925073
Second Tube Model
Straton
Second Tube Replacement Date
01/18/2019
Is this second tube arcing?
No
Second Tube Statistics
Tube B: Replaced 1/18/19 Tube Serial Number: 593321804 Number of scans: 121,278 KWs Since Tube Install: 5.7785e + 006 Tube Scan Seconds: 226,335 System Scan Seconds: 581,055
CT Software Options
✩ ANY OPTIONS LISTED ARE 'PERMANENT.' ✩ GET WORKLIST CAP3D_FILTER_85D CAP3D_FILTER_MIP CAP3D _MAIN CAP3D_VOIMODE CARDIO_PRO CARDIO_RETRO BOLUS_TRACK CARE_DOSE SYNGO_GENERAL_LICENSE CAP3D_FILTER_VRT CAP3D_EDITOR MPPS SUPPORT VOLUME WORKFLOW EXTENDED_FOV CTAPP_MAIN UHR_03 UHR CAPSO BONEREMOVAL DICOM_SR_VIEWER CTAPP_FILTER_VRT CTAPP_FILTER_MIP CTAPP_FUSIONBASE CTAPP FUSIONCUIPVIEW CTAPP_FUSIONLAYOUT CARDIO_BESTPHASE_FINDING DUAL_ENERGY_SCAN_RECON CTAPP_FILTER_SSD CT_NEURO_DSA CTAPP_PCT_NEURO CTAPP_CVF _PHASEVIEWER VOL PERFUSION_SCAN MAX_POWER SCAN AUTOREGION CARE_DOSE_ADJUST CARE_DOSE_PROFILE CARE_DOSE_ DASHBOARD DEFINITION_ FLASH VOL PERFUSION CARDIOSEO CARDIO HALFBEAT SPIRAL HIGHPITCH CARE_DOSE_X_CARE CARE_DOSE AUTOKY SCAN GUIDE RECON SPINE REGION RECON_ITERATIVE_STEP1 DUAL ENERGY FAST MR_Support i
Detector Type
STELLAR
Additional Processing Workstation Included?
Yes, there is a second workstation
Phantom(s) Included?
Yes
Egress Description
MGH is mandating the use of OB Hill as riggers, as they're one of the best rigging teams in New England. MGH is paying for it, all you have to do is deinstall it on 3/23. OB will bring it to the dock.
Injector Included?
No

Images

Equipment Listing Images Gallery (7 images)
Click image to zoom in
Previous Review Next Review
Tube Statistic Screen Images Gallery (2 images)
Click image to zoom in
Previous Review Next Review
Damage, Issues, or Problems: Gallery (3 images)
Click image to zoom in
Previous Review Next Review
Software Options Screens Gallery (5 images)
Click image to zoom in
Previous Review Next Review

Documents

Notes